25 hp (18.5 kW) VFD, 3 Phase 240V, 420V, 480V
Sale!

25 hp (18.5 kW) VFD, 3 Phase 240V, 420V, 480V

Original price was: £992.18.Current price is: £198.43.

SKU: GK3000-4T0185G Category:

Description

25 hp (18.5 kW) high performance variable frequency drive, three phase 240V, 420V, 480V for selection, IP20 enclosure.

Specification:

Basics Model GK3000-4T0185G/ GK3000-2T0185G
Capacity 25 hp (18.5 kW)
Shipping weight 8 kg
Dimension 330*200*200 mm for GK3000-4T0185G/ 530*320*235 for GK3000-2T0185G
I/O Feature Rated current 37A at 380V ~ 480V, 75A at 220V ~ 240V
Input voltage 3 phase 240V /420V /480V AC ±15% (Optional)
Input frequency 50Hz/ 60Hz
Output voltage 3 phase AC 0~input voltage
Output frequency 0Hz~1000Hz
Over load capacity 150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control Feature Control mode V/F control;
Sensorless vector control;
Communication RS485
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity 5%-95%, without condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Impingement and oscillation Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive undervoltage
The undervoltage is a problem that we often encounter in using VFD. It is mainly because of the main circuit voltage is too low (220V series below 200V, 380V series below 400V). The main reason: One circuit of rectifier bridge damage or one circuit of SCR does not work correctly, all these can lead to undervoltage. Moreover, the main circuit contactor damage resulting DC bus has voltage loss in the charge resistance may lead to undervoltage. And the voltage detection circuit failure may also cause undervoltage problem.
For example, a 25hp VFD displays “Uu” after power on. Check the rectifier bridge charge resistance and find no problem, but haven’t heard a sound of the contact action after power on. Because this VFD charging circuit doesn’t use SCR but depend on the contactor attracting to complete the charging process, so that the failure may be caused by the contactor, control circuit or power supply. Remove the contactor, and individually connect 24V DC, the contactor is working properly. And then check the 24V DC power supply and find the voltage regulator tube is damaged. After replacing it, VFD is working properly.