5 kVA 100 kV AC DC Automatic Hipot Tester
Sale!

5 kVA 100 kV AC DC Automatic Hipot Tester

Original price was: £2,906.00.Current price is: £298.98.

SKU: ATO-HT-5100A Category:

Description

5 kVA 100 kV AC DC automatic hipot tester can directly measure the AC leakage current on the high voltage side, the range is 0-50ma, if you want to measure the DC high voltage side (0-140kV) leakage current, you need to add an additional DC milliampere meter, the range is 0-1.999ma.

Control Module Specifications

  • Model: ATO-HTGTB-5100A
  • Power Supply: AC 220V±10%, 50/60Hz
  • Rated Power: 5kVA
  • Output Voltage: 0~250V
  • Input Current: 0~22.7A
  • Time Range: 0-9999S
  • Voltage Resolution: 0.1kV
  • Current Resolution: 0.1mA
  • Measurement Accuracy: ≤2%
  • Ambient Temperature: 0~40℃
  • Ambient Humidity: RH≤85%
  • Gross Weight: 29kgs
  • Package Dimension: 500*370*450mm

Test Transformer (HV Unit) Specifications

  • Output Voltage Waveform: Sine Wave
  • Output Waveform Distortion Rate: ≤1%.
  • No-Load Loss: 0.2%~0.35%
  • Induced Voltage Level: 1.1Uo/1min.
  • Surface Temperature Rise: <55℃
  • Rated Capacity: 5kVA
  • Rated Input Voltage: 0~200V
  • Rated Input Current: 25A
  • Testing Voltage: AC 100kV
  • Rated Output Current: 50mA
  • Output DC High Voltage: 140kV
  • Hipot Time: 1min
  • Gross Weight: 94kgs
  • Package Dimension: 500*430*1230mm
  • Permissible Continuous Operating Time at Rated Capacity: 0.5 hours (Long-Running Transformers Can be Ordered)
  • Consecutive Running Times: Below 10kVA, Each Interval of 2 Hours, Allows Continuous Operation of 0.5 hours; Above 15kVA, Every 4 hours, Allowing Continuous Operation for 0.5 hours; Allows Continuous Operation for 4 hours at Half Rated Voltage And Half Rated Current.

Panel Descriptions

  • There are miniature thermal printers in AC and DC high voltage test equipment. Press the print button on the panel to print out the results.
  • The contrast of the LCD display can be adjusted.
  • Turn on the indicator light, which will light up when the test starts.
  • Zero indicator light. When the voltage regulator is at the zero position, this lamp will light.
  • Alarm indicator. When a fault or protective action occurs, the light is on.
  • LCD screen, 320X240 dot matrix, white backlight.
  • Wiring diagram, refer to the wiring diagram for AC and DC testing.
  • Keyboard, interactive terminal between user and device.
  • Buzzer, sound alarm.
  • Emergency stop button, press this button to cut off the power and end.

AC Test Wiring Diagram