100 MHz Digital Oscilloscope, 2 Channels, 1 GSa/s
Sale!

100 MHz Digital Oscilloscope, 2 Channels, 1 GSa/s

Original price was: £841.59.Current price is: £168.31.

SKU: ATO-SCOPE-100M2 Category:

Description

High-accuracy dual-channel digital oscilloscope with 100 MHz bandwidth, 1 GSa/s sampling rate, 8 bits vertical resolution. Digital oscilloscope has the advantages of waveform triggering, storage, display, measurement, and waveform data analysis and processing.

Specification

Model ATO-EDS-102C
Bandwidth 100 MHz
Channel 2+ external trigger
Sample rate 1 GSa/s
Acquisition model Sample, Peak detect
Record length 10M
Display 8 inch LCD
Waveform refresh rate 10000 wfrms/s
Input coupling DC, AC, Ground
Probe attenuation 1X, 10X, 100X, 1000X
Input Impedance 1MΩ ± 2%, in parallel with 10pF ± 5pF
Max. input voltage 400V (DC+AC, PK – PK)
Bandwidth limit(typical) 20MHz / Full bandwidth
Sampling rate range 2ns/div ~ 100s/div,step by 1-2-5
Vertical Resolution 8 bits
Sensitivity Resolution 2mV/div~10V/div
Low Frequency(-3db) ≥10 Hz (at input, AC coupling)
Rise time (at input, Typical) ≤5.8ns
Trigger type Edge
Trigger model Auto, Normal, single
Trigger level range ±6 div from the screen center
Automatic measurement Vpp, Vavg, Vrms, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot,
Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, DelayA→B , DelayA→B
Cursor measurement ΔV, ΔT, ΔT&ΔV between cursors,auto cursor
Dimension 340*155*70mm
Weight 1.8kg


Accessories

  • Power cable
  • USB cable
  • Probe
  • Probe Adjust
  • Quick Guide

Dimension

Details

Tips: When should the oscilloscope sample rate be considered?

Bandwidth is dependent on the object being measured. On the premise that the bandwidth is satisfied, it is hoped that the minimum sampling interval (the reciprocal of the sampling rate) can capture the signal details you need. When selecting a sine wave, the bandwidth of the oscilloscope should be more than 3 times the frequency of the measured sine signal, and the sampling rate should be 4 to 5 times the bandwidth, which is actually 12 to 15 times the signal; for other waveforms, Make sure the sampling rate is high enough to capture signal details. If you are using an oscilloscope, you can verify whether the sampling rate is sufficient by the following method: Stop the waveform and zoom in on the waveform. If you find changes in the waveform (such as certain amplitudes), it means that the sampling rate is not enough, otherwise it will be fine. In addition, point displays can also be used to analyze whether the sampling rate is sufficient.

Reviews

There are no reviews yet.

Be the first to review “100 MHz Digital Oscilloscope, 2 Channels, 1 GSa/s”

Your email address will not be published. Required fields are marked *